An EU MDR gap assessment compares what you have today (technical documentation, clinical evidence, post-market system and quality management system) with what the EU Medical Device Regulation (EU MDR 2017/745) requires. You get a clear list of the gaps, in priority order, and a plan to close them before a Notified Body finds them.
What is an EU MDR gap assessment?
It is an independent review of your device files and processes against the MDR. Each requirement is checked against the evidence you hold, and every gap is recorded with what is missing, why it matters and what it would take to fix.
The result is not a pass or fail. It is a working plan your team can act on, sized to your devices and your timeline.
When manufacturers ask for one
- Moving legacy MDD devices to the MDR, before the 2027 and 2028 transition deadlines
- Preparing a first CE marking under the MDR
- After Notified Body findings, to see whether the problem is one document or the whole file
- Before a surveillance or recertification audit
- Changing Notified Body, or taking over a device from another company
- Adding a new device or variant to an existing technical file
What we assess
The scope follows your devices. For most manufacturers it covers these areas:
| Area | What we check | MDR reference |
|---|---|---|
| Classification and conformity route | Device class under the Annex VIII rules, the right conformity assessment route, and whether a Notified Body is needed | Article 51–52, Annex VIII |
| Technical documentation | Structure and completeness against Annex II, consistency of intended purpose and claims across every document | Annex II |
| General safety and performance requirements | GSPR checklist, the evidence behind each requirement and the standards applied | Annex I |
| Risk management | Risk file aligned with ISO 14971 and linked to design, labelling and post-market data | Annex I, Chapter I |
| Clinical evaluation | Clinical evaluation plan and report, literature search, equivalence, sufficiency of clinical evidence for every claim | Article 61, Annex XIV |
| Post-market surveillance | PMS plan, PMS report or PSUR, PMCF plan and report, vigilance and trend reporting | Articles 83–92, Annex III |
| Quality management system | QMS procedures required by the MDR, beyond ISO 13485, and how they connect to the technical file | Article 10(9) |
| Person responsible for regulatory compliance | PRRC appointment, qualifications and responsibilities | Article 15 |
| Labelling and instructions for use | Label and IFU content, symbols and language requirements | Annex I, Chapter III |
| UDI and EUDAMED | Basic UDI-DI and UDI-DI assignment, actor and device registration | Articles 27–29 |
If you only need part of this, for example clinical evaluation or post-market surveillance, we can assess that area on its own.
How it works
- Scoping call. We agree the devices, classes, areas and deadline, and confirm the timeline.
- Document review. You share the files under an NDA. We review them against the MDR, the relevant MDCG guidance and the harmonised standards you apply.
- Short interviews. We speak with the people who own the documents, to understand how things work in practice, not just on paper.
- Gap report and plan. You receive the report and a remediation plan in priority order.
- Walk-through. We take your team through the findings and answer questions, so everyone knows what to do first.
What you receive
- A gap report: every gap with the MDR reference, what is missing and the evidence needed
- A priority for each gap, based on how likely a Notified Body is to raise it and how much it could delay certification
- A remediation plan with the order of work, the effort involved and who should own each task
- A one-page summary for leadership: the risks to timeline, cost and market access in plain business terms
Free of charge
The gap assessment is free. It starts with our Readiness Check, a guided conversation of 10 to 60 minutes that gives you a readiness score and the biggest risks, and goes as deep as your devices need. You pay only if you ask us to help close the gaps, at the prices on our pricing page.
Related topics
For more on the areas we review, see technical documentation, clinical evaluation, post-market surveillance, PMCF planning, the quality management system and UDI and EUDAMED. Costs for closing the gaps are on our pricing page.
Not sure how far your file is from the MDR?
Tell us about your devices and deadline. We will scope the assessment with you and confirm the timeline before any work starts.